Reports until 16:31, Monday 14 May 2012
H2 SEI
vincent.lhuillier@LIGO.ORG - posted 16:31, Monday 14 May 2012 (2844)
ISI-BSC8 readiness

Last week-end, we took a last set of transfer functions to build a nice reference and confirm that the ISI is ready. Note that some resonances (17Hz, 26Hz) observed in corner 2 (horizontals) during the previous measurements disappeared. I have attached a transfer functions comparison that illustrate the problem in stage 2 corner 2. The SUS crew worked intensively on the QUAD to solve rubbing issues, touching flags, miscellaneous adjustments, etc...; it can explained the differences between the two measurements. I superposed 3 horizontal transfer functions in corner 2 :

The last set of transfer functions can be found at:

https://svn.ligo.caltech.edu/svn/seismic/BSC-ISI/H2/ITMY/Data/Figures/Transfer_Functions/Measurements/Undamped/

*2012_05_12*

Non-image files attached to this report