I've added the following channels to the framebuilder:
$(IFO):SUS-$(OPTIC)_L3_OPLEV_SEG1_IN1 2048
$(IFO):SUS-$(OPTIC)_L3_OPLEV_SEG2_IN1 2048
$(IFO):SUS-$(OPTIC)_L3_OPLEV_SEG3_IN1 2048
$(IFO):SUS-$(OPTIC)_L3_OPLEV_SEG4_IN1 2048
which required adding these channels to the
${userapps}/release/sus/common/models/QUAD_MASTER.mdl
then recompiling, reinstalling, restarting, and restoring the QUAD test mass models:
${userapps}/release/sus/h2/models/h2susitmy.mdl
${userapps}/release/sus/h2/models/h2susetmy.mdl
Before restarting, I created new safe.snap files, in
/opt/rtcds/userapps/release/sus/h2/?tmy/h2sus?tmy_safe.snap
in order to capture the new optical lever calibration.
After restarting, I restored to the following snap files:
/ligo/cds/lho/h2/burt/2012/07/27/14:00/h2sus?tmyepics.snap