FAMIS 26301
Laser Status:
NPRO output power is 1.828W (nominal ~2W)
AMP1 output power is 64.52W (nominal ~70W)
AMP2 output power is 136.7W (nominal 135-140W)
NPRO watchdog is GREEN
AMP1 watchdog is GREEN
AMP2 watchdog is GREEN
PDWD watchdog is GREEN
PMC:
It has been locked 0 days, 11 hr 34 minutes
Reflected power = 22.33W
Transmitted power = 104.0W
PowerSum = 126.3W
FSS:
It has been locked for 0 days 1 hr and 1 min
TPD[V] = 0.7807V
ISS:
The diffracted power is around 2.4%
Last saturation event was 0 days 1 hours and 2 minutes ago
Possible Issues: (both are known)
AMP1 power is low
PMC reflected power is high