Monthly FAMIS Check (#26494)
T240 Centering Script Output:
Averaging Mass Centering channels for 10 [sec] ...
2024-10-04 09:08:54.264102
There are 14 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -0.745 [V]
ETMX T240 2 DOF Y/V = -0.637 [V]
ETMX T240 2 DOF Z/W = -0.529 [V]
ITMX T240 1 DOF X/U = -1.51 [V]
ITMX T240 1 DOF Y/V = 0.325 [V]
ITMX T240 1 DOF Z/W = 0.447 [V]
ITMX T240 3 DOF X/U = -1.563 [V]
ITMY T240 3 DOF X/U = -0.773 [V]
ITMY T240 3 DOF Z/W = -1.934 [V]
BS T240 1 DOF Y/V = -0.394 [V]
BS T240 3 DOF Y/V = -0.307 [V]
BS T240 3 DOF Z/W = -0.49 [V]
HAM8 1 DOF Y/V = -0.475 [V]
HAM8 1 DOF Z/W = -0.786 [V]
All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = -0.083 [V]
ETMX T240 1 DOF Y/V = -0.1 [V]
ETMX T240 1 DOF Z/W = -0.159 [V]
ETMX T240 3 DOF X/U = -0.106 [V]
ETMX T240 3 DOF Y/V = -0.165 [V]
ETMX T240 3 DOF Z/W = -0.093 [V]
ETMY T240 1 DOF X/U = 0.009 [V]
ETMY T240 1 DOF Y/V = 0.116 [V]
ETMY T240 1 DOF Z/W = 0.173 [V]
ETMY T240 2 DOF X/U = -0.083 [V]
ETMY T240 2 DOF Y/V = 0.171 [V]
ETMY T240 2 DOF Z/W = 0.03 [V]
ETMY T240 3 DOF X/U = 0.182 [V]
ETMY T240 3 DOF Y/V = 0.029 [V]
ETMY T240 3 DOF Z/W = 0.109 [V]
ITMX T240 2 DOF X/U = 0.127 [V]
ITMX T240 2 DOF Y/V = 0.258 [V]
ITMX T240 2 DOF Z/W = 0.22 [V]
ITMX T240 3 DOF Y/V = 0.117 [V]
ITMX T240 3 DOF Z/W = 0.104 [V]
ITMY T240 1 DOF X/U = 0.078 [V]
ITMY T240 1 DOF Y/V = 0.083 [V]
ITMY T240 1 DOF Z/W = -0.061 [V]
ITMY T240 2 DOF X/U = 0.054 [V]
ITMY T240 2 DOF Y/V = 0.185 [V]
ITMY T240 2 DOF Z/W = 0.092 [V]
ITMY T240 3 DOF Y/V = 0.066 [V]
BS T240 1 DOF X/U = -0.162 [V]
BS T240 1 DOF Z/W = 0.087 [V]
BS T240 2 DOF X/U = -0.09 [V]
BS T240 2 DOF Y/V = 0.007 [V]
BS T240 2 DOF Z/W = -0.113 [V]
BS T240 3 DOF X/U = -0.206 [V]
HAM8 1 DOF X/U = -0.28 [V]
Assessment complete.
STS Centering Script Output:
Averaging Mass Centering channels for 10 [sec] ...
2024-10-04 09:22:39.265893
There are 1 STS proof masses out of range ( > 2.0 [V] )!
STS EY DOF X/U = -2.389 [V]
All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.514 [V]
STS A DOF Y/V = -0.927 [V]
STS A DOF Z/W = -0.438 [V]
STS B DOF X/U = 0.323 [V]
STS B DOF Y/V = 0.945 [V]
STS B DOF Z/W = -0.432 [V]
STS C DOF X/U = -0.723 [V]
STS C DOF Y/V = 0.743 [V]
STS C DOF Z/W = 0.539 [V]
STS EX DOF X/U = -0.224 [V]
STS EX DOF Y/V = -0.05 [V]
STS EX DOF Z/W = 0.084 [V]
STS EY DOF Y/V = 0.007 [V]
STS EY DOF Z/W = 1.209 [V]
STS FC DOF X/U = 0.24 [V]
STS FC DOF Y/V = -1.04 [V]
STS FC DOF Z/W = 0.636 [V]
Assessment complete.