For FAMIS 26303:
Laser Status:
NPRO output power is 1.818W (nominal ~2W)
AMP1 output power is 64.55W (nominal ~70W)
AMP2 output power is 137.7W (nominal 135-140W)
NPRO watchdog is GREEN
AMP1 watchdog is GREEN
AMP2 watchdog is GREEN
PDWD watchdog is GREEN
PMC:
It has been locked 0 days, 22 hr 2 minutes
Reflected power = 22.1W
Transmitted power = 104.0W
PowerSum = 126.1W
FSS:
It has been locked for 0 days 0 hr and 7 min
TPD[V] = 0.8089V
ISS:
The diffracted power is around 2.4%
Last saturation event was 0 days 0 hours and 7 minutes ago
Possible Issues:
AMP1 power is low
PMC reflected power is high