ryan.crouch@LIGO.ORG - posted 21:43, Friday 04 October 2024 - last comment - 13:51, Saturday 05 October 2024(80475)
Locklosses today, FSS

More investigation similar to alog80358

NLN 1412064049 lockloss tool, no tag, FSS chans looks stable.

AS_A_DC and IMC-TRANS loose lock within ~250 ms

PREP_DC_READOUT_TRANSITION 1412066248 lockloss tool, FSS tag

AS_A_DC and IMC-TRANS loose lock within 1 ms of each other, but the FSS chans look stable before hand

NLN 1412077192 lockloss tool, tool failed

AS_A_DC and IMC-TRANS loose lock within ~5 ms, small FSS glitching starts almost 2 mins before LL, large glitch 1/2 a sec before

NLN 1412084422 lockloss tool, No FSSery

AS_A_DC and IMC-TRANS loose lock within ~250 ms

NLN 1412092628 lockloss tool, FSS tag

AS_A_DC and IMC-TRANS loose lock within ~5 ms, FSS glitching starts 5 secs before LL

NLN 1412101888 lockloss tool, FSS tag

AS_A_DC and IMC-TRANS loose lock within ~250 ms

TRANSITION_FROM_ETMX 1412105312 lockloss tool, FSS tag

AS_A_DC and IMC-TRANS loose lock within ~ 13 ms, the FSS starts glitching 40 seconds before LL, FSS_PC_MON_OUTPUT starts rising ~40 seconds before LL

LOW_NOISE_ESD_ETMX 1412113952 lockloss tool, no FSSery

AS_A_DC and IMC-TRANS loose lock within ~250 ms

NLN 1412131865  lockloss tool, FSS tag

AS_A_DC and IMC-TRANS loose lock within ~1 ms, there's a FSS glitch 1 second before the LL

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 22:32, Friday 04 October 2024 (80477)Lockloss, OpsInfo, PSL

To summarize, Ryan looked at 8 locklosses from today, 6 of them had the FSS tag, 5 of them had the IMC loose lock withing 15ms of the IFO losing lock, and only 3 of them had the pattern that Ian and Camilla found was normal in O4a, where the IMC looses lock ~250 ms after the IFO losses lock.  This FSS issue seems to be having a serious impact on our duty cycle.

I had a helpful conversation with Rick this afternoon about this issue, he sugested that we trying looking for the glitches in other places in the PSL, so that we could think about tests where we don't run some of the feedback servos and see if we still see the issue. I made an ndscope template with all the PSL fast channels I could find, it is saved in sheila.dwyer/ndscope/PSL/PSL_fast_channels.yaml

Looking at 1412111658 with this scope, it looks like several of these channels that we are saving at a fast rate might not be connected, for example the OSC and HPL channels are around 0.  The only other channel that clearly shows these glitches is H1:PSL-PWR_NPRO_OUT_DQ. 

Request for operators:  If you are having locking difficulties over the weekend, it may be due to the PSL/FSS problems.  To help narrow down the cause of the problem one could sit for an hour or two with the FSS unlocked, and the ISS unlocked. If the glitches show up in the NPRO channel even without these servos locked, then we will know that the problem is not from the FSS, but from the NPRO. 

Images attached to this comment
ryan.crouch@LIGO.ORG - 13:51, Saturday 05 October 2024 (80484)ISC, Lockloss, PSL

Using Sheilas template for a few of these LLs.

1412077192

NLN LL, It looks like the FSS started glitching first then the NPRO.

1412105312

TRANSITION_FROM_ETMX LL, here it looks like the NPRO saw the first glitch then the FSS started glitching.

1412131865

NLN  LL, the NPRO power starts dropping 28 seconds before LL then the ISS, FSS, PMC and NPRO all glitch a ms before LL.

1412066248

PREP_DC_READOUT_TRANSITION LL, not much going on here, some small FSS glitches and PSL_ILS_MIXER drops.

1412092628

NLN LL, the FSS and NPRO seem to glitch at the same time ~5 sec before the LL, glitching gets more frequent closer to the LL.

Images attached to this comment
Displaying report 1-1 of 1.