Displaying report 1-1 of 1.
Reports until 14:00, Tuesday 21 January 2025
H1 GRD (ISC)
ryan.crouch@LIGO.ORG - posted 14:00, Tuesday 21 January 2025 (81256)
ISC_LOCK PRMI/DRMI counters added

I've added some logic to ISC_LOCK in DRMI and PRMI to check if we've already tried PRMI, and or CHECK_MICH. Two counters are created and = 0 in each acquisition. On our second pass through PRMI or DRMI in an aquisition the POPAIR timers will be doubled and the threshholds will be halved. The changes have been svn commited.