Shiela and I put back in the SRCL ASC and LSC offsets we found in 81792 to maximize thew coupled cavity poll. Again, the range didn't increased, the FCC increased ~3HZ but hkappa_C decreased ~0.5%. We planned to improved OMC alignment to bring back up the range and kappa_C. Plot attached.
We started repeating the OMC ASC injections form 78616, but this saturated the OMC SUS so we aborted and decided that any gains made would be very small and not worth the time. Reverted SRCL ASC and LSC offsets.