Reports until 22:00, Wednesday 15 January 2025
H1 CDS
david.barker@LIGO.ORG - posted 22:00, Wednesday 15 January 2025 - last comment - 09:33, Thursday 16 January 2025(82303)
Single Long Range Dolphin IPC receive errors on end station models for channels sent by the h1lsc model

At 17:48:23 Wed 15jan2025 PST all end station receivers of long-range-dolphin IPC channels originating from h1lsc saw a single IPC receive error.

The models h1susetm[x,y], h1sustms[x,y] and h1susetm[x,y]pi all receive a single channel from h1lsc and recorded a single receive error at the same time. No other end station models receive from h1lsc.

On first investigation there doesn't appear to be anything going on with h1lsc at this time to explain this.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 09:19, Thursday 16 January 2025 (82307)

FRS33085 is an umbrella ticket covering any IPC errors seen during O4.

Yesterday's IPC receive error was the fourth occurence during O4, we are averaging roughly one every six months.

david.barker@LIGO.ORG - 09:33, Thursday 16 January 2025 (82308)

I have cleared the end station SUS errors with a DIAG_REST when H1 was out of observe.