POP power measurements repeat

Sheila, Elenna

This morning while we were relocking I did a repeat of the POP air power measurements with 2W input power into the IFO, similar to what was done in 82942, this time the powers are rather different and are closer to expectations for HAM1 powers (with settings on the power meter verified).

Implied power in the PRC at 2W input power time:

  power measured

counts before any calibration is applied (INMON)

what I think this diode's calibration should be currently calibrated value of this diode
after 90/10 BS 1.6mW      
before POP X (POP X SUM) 0.83mW 940 0.88 uW/ count no calibration applied
before POPAIR B 0.22mW 141 1.56uW/count no calibration applied
POPAIR A diode 0.22mW infered from POPAIR B meas 10.9 20uW/count 55uW
POP in vac diode   260   1054uW

 

 

Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 16:12, Monday 17 March 2025 (83418)

With regards to the upcoming HAM1 vent and placement of an in-vac POP WFS, I think these results indicate that we can have ~30 mW of power on the in-vac POP WFS. At 2 W of input power, Sheila measured 0.8 mW on the POPX WFS. At 60 W input, there should be about 24 mW on the POPX WFS.

Daniel made a similar conclusion here.