ryan.short@LIGO.ORG - posted 09:01, Friday 21 March 2025 (83482)
PSL Status Report - Weekly

FAMIS 26376, last checked in alog83399

Laser Status:
    NPRO output power is 1.834W
    AMP1 output power is 70.15W
    AMP2 output power is 140.0W
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 44 days, 19 hr 39 minutes
    Reflected power = 22.58W
    Transmitted power = 106.0W
    PowerSum = 128.5W

FSS:
    It has been locked for 0 days 0 hr and 12 min
    TPD[V] = 0.7967V

ISS:
    The diffracted power is around 3.9%
    Last saturation event was 0 days 0 hours and 55 minutes ago


Possible Issues: None reported