ibrahim.abouelfettouh@LIGO.ORG - posted 07:36, Monday 31 March 2025 - last comment - 09:01, Monday 31 March 2025(83652)
OPS Day Shift Start

TITLE: 03/31 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Ryan S
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 28mph Gusts, 23mph 3min avg
    Primary useism: 0.06 μm/s
    Secondary useism: 0.21 μm/s
QUICK SUMMARY:

IFO is LOCKING in LASER_NOISE_SUPPRESSION

Today we have planned comissioning from 8:30 to 11:30 local time.

The last lockloss seems to have been caused by wind and elevated microseism, though neither seem high enough to have necessarily caused a lockloss.

Comments related to this report
camilla.compton@LIGO.ORG - 08:59, Monday 31 March 2025 (83654)DetChar, DetChar-Request

Ibrahim, Oli, Camilla

We had two 30+ minute range drops last night, plot attached. Looks to be mainly under 60Hz from the OMC BLRMs, plot.

Doesn't appear to be sqz, EX ground motion 83233, or CO2 ISS channel 82728 related. Oli also checked this wasn't PI related 82944.

Images attached to this comment
oli.patane@LIGO.ORG - 09:01, Monday 31 March 2025 (83656)SUS

Confirmed not the PIs for either range drop (drop1, drop2). There was a small drop in range a few minutes before the second range drop around the same time as PI31 had a small ringup, but zooming in, the ringup happened multiple minutes before and so doesn't account for that quick drop either(ndscope3).

Images attached to this comment