david.barker@LIGO.ORG - posted 09:17, Saturday 05 April 2025 - last comment - 10:36, Saturday 05 April 2025(83747)
h1daqnds1 having issues serving data, please use h1daqnds0 for now while we work on this

Note that the web trends use nds0 and are updating.

Comments related to this report
david.barker@LIGO.ORG - 10:20, Saturday 05 April 2025 (83748)

FRS33784 ticket created for this issue.

david.barker@LIGO.ORG - 10:23, Saturday 05 April 2025 (83749)

Jonathan restarted rts-daqd on h1daqnds1 at 09:37 Sat 05apr2025PDT which cleared the immediate issue.

It appears that nds1 had a connection burst of over 300 connections requests at 23:30 Fri 04apr2025PDT which caused the issue. The daqd process continued to run after that but was no longer accepting any connection requests until the restart this morning.

david.barker@LIGO.ORG - 10:36, Saturday 05 April 2025 (83751)

I rebooted nuc5 at 10:28 to get the Seismic BLRMS FOM running again. I think the other FOMs can wait till Monday.