david.barker@LIGO.ORG - posted 08:37, Wednesday 09 April 2025 - last comment - 17:10, Wednesday 09 April 2025(83828)
MX weather station wind speed sensor not working

Starting around 22:13 Tue08apr2025 the MX weather station wind speed anemometer stopped recording. The other MX sensors, for example outside temperature, continue to run.

Attachment shows wind speed and temp for EX top row, and for MX bottom row.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 08:46, Wednesday 09 April 2025 (83829)
david.barker@LIGO.ORG - 17:10, Wednesday 09 April 2025 (83846)

Literally minutes after I made this alog, unbeknownst to me, it fixed itself. I drove to MX this afternoon and visually confirmed the paddles were turning and appared to be unrestricted. The freeze between 10pm Tue and 9am Wed is still a mystery.