Reports until 10:15, Monday 23 June 2025
H1 TCS (ISC)
camilla.compton@LIGO.ORG - posted 10:15, Monday 23 June 2025 - last comment - 10:46, Monday 23 June 2025(85238)
Stepped CO2 powers down from 1.7W to 0.9W each into IFO

Elenna, Sheila, Kevin, Matt, Camilla

For some thermalization tests, at 17:05UTC we stepped CO2 powers down from 1.7W to 0.9W each into IFO. Expect majority of thermalization to take ~1hour.

Beforehand, Sheila plugged in the freq noise injection cables in the LVEA PSL racks and Elenna turned on the AWG_LINES guardian.

Comments related to this report
elenna.capote@LIGO.ORG - 10:46, Monday 23 June 2025 (85245)DetChar

I'm adding a detchar tag here in case anyone is wondering where all the lines are coming from in the data around this time- these are purposefully injected lines. If AWG_LINES is injecting, it will be in state 10. When IDLE (no injections), it is in state 2.