Reports until 11:38, Wednesday 25 June 2025
H1 ISC
sheila.dwyer@LIGO.ORG - posted 11:38, Wednesday 25 June 2025 (85328)
OMC QPD offsets updated

Matt Todd, Sheila Dwyer

We moved the OMC alignment a bit in pitch while watching for a response in kappa C. The attached screenshots show the updated pitch offsets that have been accepted in safe and observe.   The next screenshot shows us stepping this around. 

Overall, we improved the optical gain by something like 0.5 %.  We would like to return to the yaw offsets to see if we can recover the 1% optical gain that we lost during the vent.

Images attached to this report