Reports until 12:36, Monday 30 June 2025
H1 GRD (ISC)
oli.patane@LIGO.ORG - posted 12:36, Monday 30 June 2025 (85435)
PRCL2 GAIN adjustment added to THERMALIZATION guardian

Elenna, Sheila, Oli

I've added thermalization ramping for the PRCL2 gain so that it ramps from 1.0 to 1.9 over the first 75 minutes at max power. The 'unthermalized' (1.0) and 'thermalized' (1.9) values are taken from lscparams in the new dictionary 'prcl2_gain', so any changes to be made in the future to those values should be set in that dictionary, and then the THERMALIZATION guardian reloaded so that it grabs those new values.

This addition is pretty much a copy of the way we ramp the SRCL offset, but for PRCL gain of course..

This change to the THERMALIZATION guardian as well as the dictionary addition to lscparams have been committed to svn as r32157.

Images attached to this report