Reports until 10:38, Monday 18 August 2025
H1 SQZ
camilla.compton@LIGO.ORG - posted 10:38, Monday 18 August 2025 - last comment - 12:16, Wednesday 27 August 2025(86414)
DHARD, SRCL1 anmd Camera Offset Changes with Mid-sqz at 5kHZ
Elenna, Jennie, Camilla. Contining from 86361
 
We saved  H1:OMC-DCPD_524K_A2_IN1 data with the PD sum, it was already changed from last week as in  85937. DTT saved as /ligo/home/camilla.compton/Documents/sqz/templates/dtt/20250819higher_order_modes.xml screenshot attached. Elenna opened POP beamdiv.
Changed DHARD/SRCL1 settings with H1:ASC-{SRCL1,DHARD}_{P,Y}_OFFSET and the camera offsets in steps of +/-1 as in 76695Didn't see a change with DHARD or camera offsets, found improvement with SRCL1 PIT and YAW,
 
Starting angle is (-)133, took SQZ_ANG SERVO to DOWN. After each step of SRCL1/camera offsets/DHARD, we changed SQZ angle to get level back to 4dB ASQZ, as our 5kHz modes look clearest here.
To get mean sqz, pause SQZ_MANAGER, SQZ_LO_LR to DOWN, ADF off, SQZ_FC to MISALIGNED.
 
Type Time (UTC) Angle DTT Ref Notes
SQZ 15:30:00 - 15:35:00 (-)133 ref 0  
FDS Mid - SQZ 15:37:00 - 15:39:00 (-)111 ref 1 At 4dB ASQZ
FDS Mid SQZ, SRM YAW -1urad (offset -0.3) 15:47:00 - 15:49:00 (-)108 ref 2 Made better today and in 86363
Mid SQZ, , SRM YAW -1urad,  +8cts DHARD YAW 15:51:30  - 15:53:30 (-)108 ref 3 No change at 5 or 10kHz
Mid SQZ, , SRM YAW -1urad,  CAM3Y -1count 16:04:30 - 16:06:30 (-)108 ref 4 Loop takes ~5 minutes to converge, buildups worse. No change at 5 or 10kHz.
Mid SQZ, , SRM YAW -1urad,  CAM3Y +1count 16:15:30 - 16:16:30 (-)108 not taken Builds-ups same as normal. No change at 5 or 10kHz.
Mid SQZ, , SRM YAW -1urad, SRM PIT +2urad (offset +0.6) 16:23:00 - 16:25:00 (-)110 ref 5 Buildups worse, saw 5kHz was a little worse at 5kHz with +0.3 so went further. DHARD PIT started to grow at 1Hz.
Mid SQZ, , SRM YAW -1urad, SRM PIT -1urad (offset -0.3) 16:27:00 - 16:29:00 (-)107 ref 6 5kHz better
Mid SQZ, SRM YAW -1urad, SRM PIT -2urad (offset -0.6) 16:30:00 - 16:32:00 (-)106 ref 7 5kHz slightly worse
Mean SQZ 16:35:00 - 16:37:00 N/A ref 8  
 
Best for 5kHz is -0.3 on both SRCL PIT and YAW. We then took the data for the SRCL offset SQZ brontosaurs plots at these (-0.3,-0.3) SRCL1 offsets, as in 8479485362. Plot saved in camilla.compton/Documents/sqz/templates/dtt/20250818_SQZdata.xml and attached.
 
Type Time (UTC) SRCL Offset Angle DTT Ref
FIS SQZ 16:42:30 - 16:45:30 -382 (-)124 ref 1
FIS SQZ 16:48:30 - 16:51:30 -200 (-)153 ref 2
FIS SQZ 16:58:30 - 17:01:30 0 (-)224 ref 3
No SQZ 17:02:30 - 17:05:30 -382 N/A ref 0

Took above data at NLG of 16.0, checked and improved the NLG after data taken 76542.

OPO Setpoint Amplified Max Amplified Min UnAmp Dark NLG Note
80 0.108523 0.00199724 0.0067894 -1.22e-5 16.0 Without Optimizing Temp
80 0.154115 0.00199724     22.7 After Optimizing Temp
Images attached to this report
Comments related to this report
elenna.capote@LIGO.ORG - 11:53, Monday 18 August 2025 (86422)

I think we like these SRC ASC offsets, so I set up the guardian to keep them. While the overall effect is minimal, there was a small increase in the buildups that was repeatable: we switched these offsets on and off a few times as we were commissioning today and the buildups got slightly worse when they went off and slightly better when they went on. I tried to process the FIS data, and I think it shows that the overall change in the SRCL offset is minimal, but maybe someone else can confirm. Similarly, the calibration report show the fit of the sensing function is very good in the current model.

Now the guardian engages these SRC ASC offsets in the LOWNOISE_ASC state.

I have attached the results (plot one and plot two) from the FIS measurement, and the fit indicates that our current SRCL offset is fine (I think that's the correct interpretation here).

Here is a trend of the buildups and SRC ASC offsets (pitch and yaw are right on top of each other in the bottom plot). The plot shows that the buildups increase when we add these offsets and decrease when we disengage these offsets.

The calibration report is linked in this alog, and shows that the calibration model is still very good. (There are some strange errors in the report generation, but they are unrelated to this change).

Images attached to this comment
elenna.capote@LIGO.ORG - 15:08, Monday 18 August 2025 (86428)

Here is a more to-the-point executive summary of what these results today are indicating:

  • the lower frequency mode seems to be most effected by yaw SRM offsets
  • the higher frequency mode seems to be the most effected by pitch SRM offsets
  • DHARD pitch and yaw offset seem to have no effect on these modes
  • Y-arm yaw camera offsets (effectively a DSOFT offset) seem to have no effect on these modes
    • stepping both up and down by 1 ct camera offsets also made the buildups worse

A large positive SRM pitch offset caused a growing 1 Hz oscillation in DHARD pitch as well. I'm not sure what to make of that yet, but I wanted to re-emphasize for future moves.

Since we are seeing an improvement in the buildups when adding SRM offsets, I think some of the prevalence of these modes could be related to some uncontrolled AS 72 offset which is changing the SRM alignment offset. We reran dark offsets when coming back from the vent, so the dark offset change on AS 72 could be effecting the SRM alignment in some way.

elenna.capote@LIGO.ORG - 12:16, Wednesday 27 August 2025 (86598)

In a follow up discussion, Sheila and I referring Matt's slides regarding the HOMs here.

Based on Matt's work, we think that the lower frequency mode is the Y-arm mode, and the higher frequency mode is the X arm mode.

Therefore, this indicates that the SRM yaw alignment offset effected the Y arm mode and the SRM pitch alignment offset effected the X arm mode.

Also, as a follow up test, we should try CAM2 offsets, which is the X arm soft degree of freedom.

We could also try MICH alignment offsets.