new version of noise budget code: WIP

I've made a fresh start on the noise budget code, using much of the work and many of the functions from aligoNB, but in a code that should be overall simpler for us to work with.  This exists in a repo here: simplenb.

Noises estimated using the excess power method can be read in either using gps times or from a dtt template. .xml files are tracked using git lfs and read in by dttxml. If a list of gps times is provided then the code will download the data using gwpy and save asds as a .pkl file, so that the data doesn't need to be downloaded each time the budget is run. Deleteing the pkl file from the local copy will cause it to redownload the data if the user wants to change times or resolution.  The excess power projection is done using the frequency resolution of the dtt file, or right now it is hard coded to an fft length of 3 seconds for those made using a list of gps times.  The noises are rebinned to a frequency vector specified for the budget after the projections are made. 

Thermal noises are imported from gwinc.  Quantum noises are also calculated using gwinc, which is why this code needs to be run in an environment that uses Kevin's superQK branch of gwinc.  I've added a function save_quantum_params to my quantum noise modeling repo that takes a template of a yaml file including all the parameters you think are important for modeling quantum noise, and a ifo struct, which saves a yaml file with the current parameters.  This function is also available in the quantum_utils.py function in this repo, so that people can use it with any method they like of generating a gwinc model of quantum noise to incorporate into this noise budget. I think it is best to leave the quantum noise budgeting separate from this repo for now, because the code for that is still evolving.  For now I've used the quantum parameters where all the missing squeezing is explained by frequency dependent loss from 85942, the next step is to add mode mismatches to that model.

Running the budget.py script will generate noise budget plots, you can choose how many layers deep to go in plotting sub-budgets by setting that parameter in the make_all_plots function call in the final lines.  The plots attached were made using the injections that Camilla made this morning (86550), and a reference time of 20:00 UTC.

Still to do:

Non-image files attached to this report
Comments related to this report
alexandra.mitchell@LIGO.ORG - 15:34, Thursday 20 November 2025 (88189)
We used the simplenb code to make a plot for the the Stanford seismic NSF proposal, I've attached it below for reference. 

Some things which we found along the way getting this to run properly as someone offsite who doesn't have a lot of experience with cds
* We struggled with LFS and eventually manually downloaded the files needed, we couldn't get them to download via git for some reason 
* superQK environment is a branch of pygwinc https://git.ligo.org/gwinc/pygwinc 
* The aligoNB repo is also needed 
* If working offsite some lines in excess_power_utils under def import_dtt_calib should be edited to the correct directory

Hope this is useful for anyone trying to do the same offsite! 