Broad band ran before the Calibration push:
pydarm measure --run-headless bb
2025-08-28 08:03:41,609 config file: /ligo/groups/cal/H1/ifo/pydarm_cmd_H1.yaml
.....computer noises.....
Completeed successfully!
Calibration was pushed by Elena
!!! ANOTHER WILD BROADBAND Appears !!!
pydarm measure --run-headless bb
2025-08-28 08:37:10,096 config file: /ligo/groups/cal/H1/ifo/pydarm_cmd_H1.yaml
2025-08-28 08:37:10,113 available measurements:
pcal: PCal response, swept-sine (/ligo/groups/cal/H1/ifo/templates/PCALY2DARM_SS__template_.xml)
bb : PCal response, broad-band (/ligo/groups/cal/H1/ifo/templates/PCALY2DARM_BB__template_.xml)
sens: sensing function (/ligo/groups/cal/H1/ifo/templates/DARMOLG_SS__template_.xml)
act1x: actuation X L1 (UIM) stage response (/ligo/groups/cal/H1/ifo/templates/SUSETMX_L1_SS__template_.xml)
act2x: actuation X L2 (PUM) stage response (/ligo/groups/cal/H1/ifo/templates/SUSETMX_L2_SS__template_.xml)
act3x: actuation X L3 (TST) stage response (/ligo/groups/cal/H1/ifo/templates/SUSETMX_L3_SS__template_.xml)
open
restore /ligo/groups/cal/H1/ifo/templates/PCALY2DARM_BB__template_.xml
run -w
save /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20250828T153710Z.xml
"The new calibration looks good" ~Elenna circa late Aug 2025
Finally some SIMULINES :
gpstime;python /ligo/groups/cal/src/simulines/simulines/simuLines.py -i /ligo/groups/cal/H1/simulines_settings/newDARM_20231221/settings_h1_20250212.ini;gpstime
PDT: 2025-08-28 08:45:54.867509 PDT
UTC: 2025-08-28 15:45:54.867509 UTC
GPS: 1440431172.867509
....Computer noises ....
Oh no!!! : (
LOCKLOSS during Simulines!
2025-08-28 16:13:08,168 | ERROR | Aborting main thread and Data recording, if any. Cleaning up temporary file structure.
PDT: 2025-08-28 09:13:08.423541 PDT
UTC: 2025-08-28 16:13:08.423541 UTC
GPS: 1440432806.423541