Displaying report 1-1 of 1.
Reports until 16:33, Monday 01 September 2025
H1 General
oli.patane@LIGO.ORG - posted 16:33, Monday 01 September 2025 (86679)
Ops Day Shift End

TITLE: 09/01 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
INCOMING OPERATOR: Ryan C
SHIFT SUMMARY: Observing at 153 Mpc and have been Locked for over 1.5 hours. Relocking after the lockloss today went fine besides needing to touch ALSX and ALSY a bit. Weirdly, the first two times ALSX locked and turned on WFS, after a bit the WFS pulled the alignment away and caused ALSX to unlock. I set everything up to be able to turn the WFS off for the next time, but then there was no problem.
LOG:

14:30 UTC Relocking and in DRMI_LOCKED_CHECK_ASC
15:09 NOMINAL_LOW_NOISE
    15:11 Observing
    18:59 Superevent S250901cb
    19:38 Earthquake mode activated - I moved us into earthquake mode because of some ground motion that USGS hadn't seen yet
    19:46 Back to CALM
20:07 Lockloss
    - ALSX and Y needed my help for locking
    - Twice ALSX WFS pulled ALSX away and unlocked it
21:54 NOMINAL_LOW_NOISE
    21:55 Observing

Displaying report 1-1 of 1.