IMC transmission degraded after power outage, and in 60W locks since the power outage

Compaing now to a time before the power outage, the ISS diffracted power is now the same (3.6%).  The PMC transmission has dropped by 2%, and the PMC reflection has increased by 3.5%.

Looking at IMC refl, before the power outage when the IMC was locked with 2W input power.

time IMC refl refl percent of before outage MC2 trans MC2 trans % of before outage
9/10 8:12 UTC (before power outage, 2W IMC locked) 0.74   317  
9/11 00:22 UTC (IMC relocked at 2W after outage) 1.15 155% 312 98%
9/11/1:50 UTC (after first 60 W and quick lockloss, IMC relocked at 2W) 1.27 171% 310 97%
9/11 18:17 UTC (after overnight 60W lock)** had one IMC ASC loop off 2.06 278% 278 87%
9/11 19:22 UTC (after all IMC ASC on) 2.13 287% 301 95%
9/11 21:17 UTC (after sitting at 2W for 3 hours) 2.03 274% 303 95%

The attached screenshot shows that the ISS second loop increased the IMC input power during the overnight 60W lock to keep the IMC circulating power constant. 