Reports until 11:30, Friday 12 September 2025
H1 IOO
sheila.dwyer@LIGO.ORG - posted 11:30, Friday 12 September 2025 (86877)
IMC OLG measurement comparison

Ryan S, Keita, Oli, Sheila

Using the instructions found here we used the netgpib script to get data from an IMC OLG measurement (already checked yesterday 86852). 

Oli and I adapted Craig's quick tf plot script to plot two TFs on top of each other, and found some data from Oct 31st 2024 where the IMC OLG was measured with 2W input power 80979

We adjusted the gain of the 2024 measurement to match the gain of the 2024 measurement to today's for the first point.  The IMC cavity pole is at 8.8kHz, so since this measurement cuts off at 10kHz it will be difficult to get information about the IMC cavity pole from this measurement. 

This script is in sheila.dwyer/IOO/IMC_OLG/quick_2tfs_plot.py,  legend entries and file names are hardcoded not arguments.

 

Non-image files attached to this report