Displaying report 1-1 of 1.
Reports until 09:06, Monday 06 October 2025
H1 SQZ
sheila.dwyer@LIGO.ORG - posted 09:06, Monday 06 October 2025 - last comment - 12:38, Monday 06 October 2025(87309)
SFI2 temperature with ZM fringe wrapping measurements

Camilla, Sheila

We repeated a test similar to 78125, where we changed the SFI2 temperature and measured fringe wrapping by exciting ZM2 and ZM5.  The temperature of SFI2 changes the backscatter shelf amplitude seen when exciting ZM2, but not ZM5, suggesting that the source of the scattering is upstream of the isolation of SFI2.

Images attached to this report
Comments related to this report
valery.frolov@LIGO.ORG - 09:52, Monday 06 October 2025 (87311)

The attached plot shows ZM2 and ZM5 fringing measurements at LLO. The total OMC current is 50 mA.

Images attached to this comment
sheila.dwyer@LIGO.ORG - 12:38, Monday 06 October 2025 (87322)

Here's a model of our ZM fringe wrapping measurements (the same plot as in 86836, plotted with a model that's roughly emulating Valera's measurement above.  It looks like LLO has about 200pW of interferometer light reaching the filter cavity, but none of the extra scatter we see from before SFI2.

Images attached to this comment
Displaying report 1-1 of 1.