TITLE: 10/07 Day Shift: 1430-2330 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: TJ
CURRENT ENVIRONMENT:
SEI_ENV state: CALM
Wind: 2mph Gusts, 1mph 3min avg
Primary useism: 0.02 μm/s
Secondary useism: 0.13 μm/s
QUICK SUMMARY:
First things first, at Camilla's request, I did a PAUSE for TCS_ITM[x/y]_CO2_PWR Guardians---this was for a possible Matt T. test (he just walked in and was hoping for a recently-thermalized H1, but H1is only at NLN for 1.25hrs (he's contacting Sheila).
Other than that, preparing for Maintenance!
P.S. There was a dust alarm for one of the Optics Labs when I arrived
Notes On H1 Overnight: NO Wake-Up Calls; Lockloss down from 1131-1331utc (due to earthquake dropping H1 +L1); Reacquisition AUTOMATIC (no alignment run); H1 was then locked about 90min before it was intentionally unlocked for Maintenance.