oli.patane@LIGO.ORG - posted 17:24, Wednesday 22 October 2025 - last comment - 20:17, Wednesday 22 October 2025(87659)
PR3 and SR3 L and P Estimators turned off for now

Turns out that I had forgotten to turn the input on for the PR3 P estimator contribution from L (H1:SUS-PR3_M1_EST_P_FUSION_MODL_DRV_L_2GAP) (thanks to Edgard and Brian for having us even consider the estimators!), and that was causing the 0.6 Hz ASC ringups (87658). Even though we're pretty sure we found the cause, we've decided to temporarily turn off the PR3 and SR3 L and P estimators until we're back up and can verify that they are now working correctly.

Images attached to this report
Comments related to this report
brian.lantz@LIGO.ORG - 20:17, Wednesday 22 October 2025 (87670)

Thanks for catching this, Oli. I made a note in FRS ticket 35410 reminding us to make an installation script which automatically sets all the epics variables so we are more likely to get all the right settings from the beginning. 