Following up on [LHO: 87659], we found an error on the file that transfers the SR3/PR3 OSEM estimator fits posted in [LHO: 87612 LHO: 87593] into foton. Maybe this error explains the 0.67 Hz ringing that we had with the estimator ON.
The make_PR3_estimator_LP.m file was jamming the ISI fits into the M1 drive model. This was a copy-paste type error that I have resolved by now. The corrected code was committed to the SVN under revision 12752.
Next update I will make these pieces of code that commission the estimator less hardcoded to hopefully avoid repeating this mistake in the future.
These filters have been updated in both PR3 and SR3. The estimator is still off though!