Displaying report 1-1 of 1.
Reports until 16:10, Friday 24 October 2025
H1 CDS
david.barker@LIGO.ORG - posted 16:10, Friday 24 October 2025 - last comment - 16:20, Friday 24 October 2025(87732)
New SDF settings differences lists

My first SDF post today, which was based on getting archive files from subversion commits, doesn't appear to be complete and in addition may have some false positives.

I have generated new lists, this time getting the archived OBSERVE.snap files from the CDS backups of userapps by the file server.

In the directory /ligo/home/david.barker/tuesdaymaintenance/24oct2025/sdf/observe there are:

mon20oct2025/ Directory of backups as of 00:39 early monday morning

wed22oct2025/ Directory of backups as of 00:39 early wednesday morning

thu23oct2025/ Directory of snaps as of 00:39 ealy thursday morning

mon-wed_diffs.txt Text file of settings changed between the monday and wednesday backups

mon-thu_diffs.txt Text file of settings changed between the monday and thursday backups

snap_diffs.bsh Shell script to generate the diffs files

snapfiles Text file of the userapps "OBSERVE.snap" files as symbolically linked from the target directories

 

Comments related to this report
jennifer.wright@LIGO.ORG - 16:20, Friday 24 October 2025 (87733)

Didn't find any other smoking guns, just the LSC-POP_A filter selection being wrong, making the anti-whitening gain wrong (see alog #87728), which we already knew about from the commit comparison Dave did previously (see alog #87718):

-H1:LSC-POP_A_RF45_I_SW1S 1 4.12400000000000000000e+03 0xffffffff
+H1:LSC-POP_A_RF45_I_SW1S 1 1.05200000000000000000e+03 0xffffffff

-H1:LSC-POP_A_RF45_Q_SW1S 1 4.12400000000000000000e+03 0xffffffff
+H1:LSC-POP_A_RF45_Q_SW1S 1 1.05200000000000000000e+03 0xffffffff

 

Displaying report 1-1 of 1.