Displaying report 1-1 of 1.
Reports until 10:58, Monday 27 October 2025
H1 ISC
jennifer.wright@LIGO.ORG - posted 10:58, Monday 27 October 2025 (87766)
Change of reflected power from OMC during DARM offset step

I made plots of anti-symmetric power P_AS vs. power at reflected port of OMC P_OMC_REFL during the DARM offset step measurement on September 4th, (see LHO alog #86785 and 87629).

I had to use the Beckhoff reported power for this (H1:OMC-REFL_A_DC_POWER) as the front-end channel is calibrated wrongly (see LHO alog #87648).

I also plotted the P_OMC_REFL vs.  P_DCPD, ie. reflected vs. transmitted power for the OMC.

The plots for our two measurements taken at different times during IFO thermalisation are below, both were taken when OM2 was hot.

Non-image files attached to this report