Jeff and I were discussing our options for measuring the TFs for OSEM estimators for Length/Pitch and Yaw. We lay some thoughts here for future reference
The two options for getting the transfer functions are:
  1. OPTION 1: We set the M1_DAMP_Y filters to 20% gain, leaving all other M1_DAMP filters at 100% nominal gain. Measure all of the Yaw estimator transfer functions. Then, set M1_DAMP_L and M1_DAMP_P to 20% gain, leaving everthing else at 100% nominal gain. Measure all the Length/Pitch estimator transfer functions.
  2. OPTION 2: We set all three of the M1_DAMP_{L,P,Y} to 20% gain and get all measurements for L, P , and Y transfer functions. This method is faster for measurement, but needs more fitting to deal with cross-couplings to Yaw.

Here are the thougths

Given these thoughts, I think OPTION 2, 20% gain on LPY, is the way to go from now on. I think this should simplify the data collection for the HSTSs, and it will end up being less work overall. 
 