Displaying report 1-1 of 1.
Reports until 11:13, Tuesday 04 November 2025
H1 SEI (SEI)
ibrahim.abouelfettouh@LIGO.ORG - posted 11:13, Tuesday 04 November 2025 (87942)
H1 ISI CPS Sensor Noise Spectra Check - Weekly FAMIS 27396

Closes FAMIS 27396. Last checked in alog 87787

Plots look fine compared to last week but BSC High-Freq noise is elevated for these sensors:

ITMX_ST1_CPSINF_H1
ITMX_ST1_CPSINF_V1
ITMX_ST2_CPSINF_V1   

Note - it is Tues Maint. so there are people in the LVEA.

There was a 7.5Hz peak in TJ's last-week check that is now gone. It was most prominent in HAM1 it seems.

Pdf Attached.

Non-image files attached to this report
Displaying report 1-1 of 1.