Displaying report 1-1 of 1.
Reports until 04:28, Friday 07 November 2025
H1 General (CDS, Lockloss)
ryan.crouch@LIGO.ORG - posted 04:28, Friday 07 November 2025 - last comment - 07:00, Friday 07 November 2025(88001)
OPS OWL report

We lost lock and several suspension have tripped from a 5.7 from Northern Mexico. There are DACKILLs on both the ITMs, this needs a model restart I believe to fix, we are going to be DOWN for the rest of the OWL shift at least. I'll call out for help in a bit, after 6.\

The microseism is also increasing, so I'm not so sure we'd be able to relock.

Comments related to this report
richard.mccarthy@LIGO.ORG - 07:00, Friday 07 November 2025 (88002)

ITMX,ITMY -SUS, ISI, HEPI were all tripped.  I have reset all the watchdogs and and ITM spots have returned to the camera screen.  Will let the operator check the health of the system before moving on.

Displaying report 1-1 of 1.