M. Todd
Summary: I do not think the ISS is limited by the input jitter (IMC PZT) from 1-1000 Hz. I have attached the injections I've made to the IMC PZT here. Below 1Hz I suspect the ISS is dominated by the IMC motion.
|
Measurement |
Time |
File |
Notes |
| PZT PIT -> ISS OUTER RIN [1-15 Hz] | 1446913141 | /ligo/home/matthewrichard.todd/Projects/imc_injections/dtt_injections/pzt_pit_injection_1_15_Hz.xml | Dotted line is quiet time projection to ISS RIN |
| PZT YAW -> ISS OUTER RIN [1-15 Hz] | 1446913769 | /ligo/home/matthewrichard.todd/Projects/imc_injections/dtt_injections/pzt_yaw_injection_1_15_Hz.xml | Dotted line is quiet time projection to ISS RIN |
| PZT YAW -> ISS OUTER RIN [15-1000 Hz] | 1445108720 | /ligo/home/matthewrichard.todd/Projects/imc_injections/dtt_injections/pzt_yaw_injection_15_1000_Hz.xml | Dotted line is quiet time projection to ISS RIN |
| PZT PIT -> ISS OUTER RIN [15-1000 Hz] | 1445107725 | /ligo/home/matthewrichard.todd/Projects/imc_injections/dtt_injections/pzt_yaw_injection_15_1000_Hz.xml | Dotted line is quiet time projection to ISS RIN |