Successful lock using ETMY ESD, not ITMX

[Jenne, Alicia, Joan-Rene, with suggestions from Sheila]

Today we tested using ETMY to transition the ETMX ESD, rather than the usual locking procedure of ITMX.  I had checked on the guardian code for this last week, alog 87997.  It worked!  The first time we tried transitionining back to ETMX, we lost lock, but the second time that also worked.  We are currently locked at NLN and observing, having gotten here using ETMY and not any stages of ITMX for the ESD transition. This means that we're ready to try grounding the ITM ESDs, to see if that helps reduce the combs that Alicia and Joan-Rene have been investigating. 

As of now, the guardian is set to acquire lock still using the nominal ITMX ESD.  So, before we ground the ITM ESDs we'll need to modify the weights in the guardian path, to make it so that the nominal path uses the ETMY and not ITMX.

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 09:12, Monday 17 November 2025 (88137)

It turns out that I had the guardian setting up ETMY while the bias was still ramping.  RyanC moved the lines referred to in https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=88116 to be in the Run part of the guardian state, and to wait until after the bias finishes ramping.  We've now locked like this once, and it's been successful.