Fixed accelerometers underneath HAM1 + others

At some point within the last year, both the X and Y-axis accelerometers (PEM-CS_ACC_LVEAFLOOR_HAM1_X and Y) were kocked off (pictured here) the small metal cube they were mounted to. I reattached them as of Nov 11, 2025. I believe the capacitor position sensor box was pushed back into the accelerometers which knocked them off. Image 3 shows where the CPS box is in relation to HAM1 (circled in red) and image 4 shows where it is in relation to the accelerometers. 

Additionally, two other accelerometers have been remounted with epoxy in August: PEM-CS_ACC_BEAMTUBE_SRTUBE_X (remounted August 5, 2025) and PEM-CS_ACC_BEAMTUBE_YMAN_X (remounted August 12, 2025). Both had fallen off the beamtube and had been hanging in the air for an unknown amount of time until someone noticed. 