WP 12886 Reconfigure daqd systems on the DAQD 0 leg for ECR E2500314

Jonathan, Dave, Erik, Richard,

As per WP 12886 we reconfigured the DAQD 0 computers.  The goal was to combine the functionality of the data concentrator (DC0) and frame writer (FW0) into one machine, consolidating them to one machine.  This then frees up the other machine for use with pushing data into the NGDD (Next Generation Data Delivery) kafka brokers in LDAS.

At this point h1daqdc0 is no longer the data concentrator.  H1daqfw0 is the data concentrator + frame writer.

This required a few other changes:

Once this work was done and h1daqfw2 was shown to be producing identical frames to h1daqfw[01] work was able to move onto the consolidation.

The basic steps:

the H1:DAQ-DC0 epics variables are used in many places, so Dave and Jonathan configured h1daqfw0 to output H1:DAQ-DC0 epics variables, and put a small IOC together to output the set of H1:DAQ-FW0 variables we need.  This is an area we need to revisit.  One likely approach is to make use of a feature in cps_recv that outputs the daqd STATUS, CRC_CPS, CRC_SUM variables and then to move the daqd on FW0 back to outputing the FW0 variables.

This work validates that we can combine the DC and FW computers into one.

The next step is to turn the old DC machine into the producer for NGDD data.  We will run the fiber to connect it through to LDAS later this week and work on setting that system up.

My checklist for this is in the DCC https://dcc.ligo.org/T2500385