Two broadband measurements were run: one before updating calibration and one after. The one run before the update was run after we had been Locked for over 4.5 hours, so we were fully thermalized, and the second measurement run after the update was also fully thermalized
First BB measurement: 2025-11-24 19:32:44 - 19:38:03 UTC
calibration monitor screen
Results: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20251124T193252Z.xml
Second BB measurement: 2025-11-24 19:52:47 - 19:58:02 UTC
calibration monitor screen
Results: /ligo/groups/cal/H1/measurements/PCALY2DARM_BB/PCALY2DARM_BB_20251124T195252Z.xml