david.barker@LIGO.ORG - posted 08:54, Thursday 04 December 2025 (88354)
IO Chassis Timing Card Firmware Versions

On Tuesday 02dec2025 Marc upgraded the firmware version of the IO Chassis timing cards at both end stations and mid stations. This upgrade was done "in place" using a laptop connected to the JTAG port on the timing card.

The current timing card firmware versions for H1 are:

All are running 0xfe0 except the following which are running 0x635

h1omc0: upgraded some time ago during O4 to move its DUOTONE frequencies from [960/961Hz] to [1920/1921Hz]

h1susey: upgraded Mon 01dec2025 when its timing card was replaced as part of the LIGO-DAC upgrade

Upgraded by Marc Tue 02dec2025:

h1iscex 
h1iscey
h1pemmx
h1pemmy
h1seiex
h1seiey
h1susauxex
h1susauxey
h1susey