Summary of where we are in the upgrade:
h1susey
All Gen Std DACs replaced with 2 LIGO-DACs. All AI-Chassis upgraded to SCSI daisy-chain.
Timing card replaced with one having latest firmware
New models [h1iopsusey, h1susetmy, h1sustmsy, h1susetmypi]
All models running RCG-5.5.2
h1susex
All Gen Std DACs and first-gen LIGO-DAC replaced with 2 LIGO-DACs. All AI-Chassis upgraded to SCSI daily-chain.
Timing card firmware upgraded in place
New models [h1iopsusex, h1susetmx, h1sustmsx, h1susetmxpi]
All models running RCG-5.5.2
h1iscex
18bit-DAC replaced with 20bit-DAC.
Timing card firmware upgraded in place
New models [h1iopiscex, h1calex, h1pemex]
All models running RCG-5.5.2
h1iscey
Timing card firmware upgraded in place
h1seiex, h1seiey
Timing card firmware upgraded in place
h1susauxex, h1susauxey
Timing card firmware upgraded in place.
All models running RCG-5.5.2 (first test of new RCG)
h1pemmx, h1pemmy
Timing card firmware upgraded in place.