Reports until 18:40, Friday 05 December 2025
H1 General
oli.patane@LIGO.ORG - posted 18:40, Friday 05 December 2025 (88395)
Ops Day Shift End

TITLE: 12/05 Day Shift: 1530-2300 UTC (0730-1500 PST), all times posted in UTC
STATE of H1: Corrective Maintenance
INCOMING OPERATOR: None
SHIFT SUMMARY: IFO is currently in IDLE. We were eventually able to get the IMC relocked after a lot of touching up optics and the PZT, but it seems like whenever it's been unlocking, it's having more trouble relocking than usual. We ran the dither align scripts for the TMSs and ITMs, and also ran through several full or partial initial alignments trying to get everything looking better. We had issues with basically every part of initial alignment, and after finishing alignment we would still have issues with flashes looking bad, especially for PRMI. Only green arms and MICH have been consistantly looking good.

Matt has started running an inverse filter on the ITMX ring heater over the weekend.


LOG:

- initial alignments and first few relocking states

Start Time System Name Location Lazer_Haz Task Time End
15:49 FAC Eric FCES n Heating issues 16:58
15:50 CDS Richard Ends n RFM troubleshooting (EX, then EY) 16:34
16:12 FAC Kim, Nelly LVEA n Mega cleanroom recleaning 19:17
16:44 FAC Randy LVEA n Moving septum in from high bay and fork lifting around 19:51
16:45 CDS Richard LVEA n Checking on things 16:51
18:05 JAC Jennie LVEA, Prep lab n Grab parts in LVEA, then JAC table work 19:00
18:06 CDS Marc CER Mezz n Checking power supplies 18:14
18:10 VAC Gerardo LVEA n Checking on purge air 18:19
18:17 CDS Marc CER n Pulling Beckhoff chassis 3 18:40
18:18 CDS Daniel EX n Checking Bechoff chassis 19:21
18:51 SUS Betsy, Rahul High bay n Cables 18:59
19:00 PCAL Rick, Volker PCAL lab n Checking on lab 19:12
19:02 CDS Marc CER n Putting Beckhoff chassis back in 19:15
19:16 SUS Rahul LVEA n Putting things in sus storage racks 19:24
19:27 CDS Daniel, Marc EX n Checking on power supply 19:46
19:41 TCS TJ LVEA n Turning TCS power supply on 19:51
21:20 VAC Gerardo LVEA n Getting parts for AWC 21:29
21:38 SQZ Kar Meng, Eric Opt Lab n OPO work 00:04
21:38 PCAL Oli EX n Turning on PCAL X laser 22:38
21:52 JAC Jennie LVEA n Looking for parts 23:52
21:57 VAC Travis MY n Parts transportation 22:21
22:17 - Matt, Jason LVEA n Check on PSL env and plug back in IMC whitening cable 22:21
23:29 PSL Jason LVEA n Resetting PSL environmental settings 23:34