ibrahim.abouelfettouh@LIGO.ORG - posted 16:22, Friday 12 December 2025 (88502)
OPS Day Shift Summary

TITLE: 12/13 Day Shift: 1530-0030 UTC (0730-1630 PST), all times posted in UTC
STATE of H1: Planned Engineering
INCOMING OPERATOR: None
SHIFT SUMMARY:

IFO is in IDLE for Planned Engineering

TLDR - Last few big remaining lock health checks were successfully done.

First, initial alignment was ran successfully and automatically. 

We then started our day with 5 lock steps we wanted to confirm as working in the case that we could not fully lock:

To get around SRC1 P/Y instability, that would take time we don't have to fix, we locked while manually touching SRM at different times, notably: DRMI_LOCKED_CHECK_ASC, PREP_ASC_FOR_FULL_IFO, MOVE_SPOTS. However, after not being able to get past MOVE_SPOTS - couldn't keep RFPOP90 low enough with SRM touches, we tried a different method to get over the remaining checks suggested by Jenne:

  1. Stop at 25W, touch SRM (counts on H1:LSC-POPAIR_B_RF90_I_NORM_MON good if under 12)
  2. Manual to Lownoise Coil Drivers - Successful.
  3. Auto until LOWNOISE_ESD_ETMX - Successful.
  4. Manual to OMC Whitening, damp violins - Successful. Tony Damped violins.
  5. Manual to Laser Noise Suppression - Mostly successful - Ryan S took care of this with advice from Keita about the scaling of the IMC_REFL and LSC_REFL IN1/2 and Fast Gain Servo Gains.

For a very comprehensive summary of locking progress, check out Ryan S's Wonderful Alog 88498.

Lock Acquisitions:

  1. Lockloss due to SRC1 P/Y at Prep_ASC_FOR_FULL_IFO. SRM railed prior.
  2. Lockloss due to Technical Cleaning at HAM2. HAM2 WD Tripped. Cleaning stopped after this.
  3. Lockloss due to failed SRM adaptation (with ops acting as SRC1) at MOVE_SPOTS
  4. Lockloss at Laser Noise Suppression upon activation of IMC_REFL Fast Gain at 25W
  5. Lockloss at Laser Noise Suppression upon activation of IMC_REFL Fast Gain at 25W - though this time we confirmed it was likely the fast gain since Keita and Ryan S stepped through the state with gains scaled to 25W.

Meanwhile,

LOG:                                                                                                                                                                                                      

Start Time System Name Location Lazer_Haz Task Time End
15:57 SAFETY LASER HAZ STATUS LVEA N LVEA is LASER SAFE \u0d26\u0d4d\u0d26\u0d3f (\u2022_\u2022) 10:51
15:38 FAC Nellie and Kim LVEA HAM7, HAM2, HAM1 N Technical Cleaning 17:01
16:05 VAC Jordan LVEA N Purge Air Meas. 16:19
18:21 EE Marc CER N Hi-Voltage HAM7 18:29
18:53 SQZ Kar Meng, Daniel, Keita LVEA N HAM7 OPO 19:53
21:03 TCS Matt Optics, Vac Prep N CHETA work 23:18
21:51 VAC Jordan LVEA N Closing gate valves, turning on HAM1 cleanroom 23:19
22:21 ISC Jennie LVEA N Looking for camera mount 22:47
22:21 JAC Daniel LVEA N JAC cabling 00:21
22:25 SQZ Keita, Kar Meng, Daniel D. LVEA N HAM7 OPO swap 00:18
22:48 JAC Marc LVEA N JAC cabling 00:48
23:11 FIT Masayuki Arms N On a run 23:41
23:53 JAC Jennie Opt Lab N Looking for parts 00:53
00:04 JAC Masayuki Opt Lab N Joining Jennie 01:04