Reports until 17:48, Monday 15 December 2025
H1 CDS
jonathan.hanks@LIGO.ORG - posted 17:48, Monday 15 December 2025 - last comment - 17:49, Monday 15 December 2025(88531)
Replacing failing disks on cdsfs0 and cdsfs1

Another disk showed problems on cdsfs0, so I replaced it was a spare.

Cdsfs1 has numerous problems.  Zpool status is noting that sdl, sdh, sdp, sdo are bad.  It looks like the io slot for sdl may be bad (I tried replacing the disk and the system could not see it).  I replaced the sdh disk and got it resilvering.  Then sdp started resilvering (which was unexpected). I'm going to wait and see how this resilvering goes before I proceed.  The activity lights do not match my model of what zpool status is telling me.  This is an old box, and replacement/retirement may just be the better path for it.

Comments related to this report
jonathan.hanks@LIGO.ORG - 17:49, Monday 15 December 2025 (88532)

As a follow-up note, this cdsfs0/1 are old file servers.  They used to host and backup /ligo.  Now cdsf0 is just used for vm disks, and fs1 backs up fs0.

The eventual goal is to retire them.