Displaying report 1-1 of 1.
Reports until 08:03, Tuesday 16 December 2025
H1 PSL (PSL)
ibrahim.abouelfettouh@LIGO.ORG - posted 08:03, Tuesday 16 December 2025 (88538)
PSL Weekly Report - Weekly FAMIS 27622

Closes FAMIS 27622, last checked in alog 88380


Laser Status:
    NPRO output power is 1.86W
    AMP1 output power is 70.35W
    AMP2 output power is 139.5W
    NPRO watchdog is GREEN
    AMP1 watchdog is GREEN
    AMP2 watchdog is GREEN
    PDWD watchdog is GREEN

PMC:
    It has been locked 6 days, 14 hr 45 minutes
    Reflected power = 24.87W
    Transmitted power = 105.8W
    PowerSum = 130.7W

FSS:
    It has been locked for 0 days 16 hr and 45 min
    TPD[V] = 0.5086V

ISS:
    The diffracted power is around 4.5%
    Last saturation event was 0 days 18 hours and 22 minutes ago


Possible Issues:
    PMC reflected power is high