Reports until 20:56, Friday 09 January 2026
H1 IOO (IOO)
masayuki.nakano@LIGO.ORG - posted 20:56, Friday 09 January 2026 - last comment - 11:22, Tuesday 13 January 2026(88731)
JAC working log 1/8-9

[Jason, Jennie, Betsy, Keita, Sophie, Masayuki]

Initial alignment (1/8)

 


JAC wiring (1/8)


Wiring confirmation (1/9)


Optics preparation (1/9)

 

Images attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 21:59, Friday 09 January 2026 (88732)

Mirrors inspected:

Mirror status was found what was done
M2 Not ready in a lens container with foam sponge after the first cotnact was removed, which is a bad idea. Many dust particles after taking it out of the box. Painted first contact.
M3 Ready Was in the chamber, first contact still on. Removed FC while using top gun. A big dust particle in the back surface, couldn't remove with further top gun, but that's OK.
RM3 Not ready Was in the chamber, first contact still on. Removed FC while using top gun. One dust particle close to the center, couldn't remove. Painted FC.

M3 assy is in the chamber (but is still at the edge of the ISI).

M2 and RM3 optics are stored outside of the chamber.

Lens First Contact problem:

All of the lenses had at least one surface where the first contact was incredibly strongly attached. Simple pulling of the mesh won't do anything even with serious force. We wiggled the mesh in multiple directions with enormous force and the mesh started separating from the FC. Will discuss with Betsy on Monday. All of these are stored outside of the chamber.

L1 FC remains on one surface. Painted FC on top of the existing layer over the mesh. Will see if it makes the FC loose.
L2 FC remains on both surfaces.
L3 FC remains on one surface.

2" Lens Post issue:

All pieces of 8-32 variant of D1000968-v3 were manufactured incorrectly, they have 8-32 bottom screw holes so cannot be mounted on the standard ISC baseplate.

To make them usable, the bottom hole should be widened and re-tapped for 1/4-20 though there's no urgency because we were able to use the original 1/4-20 version. (It seems that this variant was requested on a wrong assumption that Siskiyou lens mount only accepts 8-32. In reality the lens mount has two screw holes, one for 8-32 and the other for 1/4-20, so this variant isn't really needed.)

corey.gray@LIGO.ORG - 11:22, Tuesday 13 January 2026 (88747)EPO

Tagging for EPO photos