Reports until 08:54, Friday 16 January 2026
H1 CDS
david.barker@LIGO.ORG - posted 08:54, Friday 16 January 2026 (88781)
Frontend Model Work Thursday 15th January 2026

Jeff, Oli, Jonathan, EJ, Erik, Dave:

On Thursday 15Jan2026 we installed Jeff and Oli's new models for:

h1susmc2, h1suspr2, h1sussr2, h1susbs

h1susitmx, h1susitmy, h1susitmpi

h1susauxb13, h1susauxb2h34

Several DAQ restarts were needed for these installs. The first DAQ restart also had an EDC restart to use updated SDF and CDSMON ini files incorporating the new model names.

The models in h1susb2h34 had two sets of restarts. After the first EJ found some IPC issues which he fixed by editing H1.ipc. All the models were then restarts a second time.

In the first block of restarts h1suspr2 had two starts, the second to fix a 18bit-DAC to 20bit-DAC change.

We had three instances of new models removing channels from the DAQ which were being sent to GDS via the broadcaster. Jonathan removed these from the broadcaster list we are working today on whether they should be added back, perhaps with a different name.

Here are the models and GDS channel lists:

h1susitmx (4):

H1:FEC-29_DAC_OVERFLOW_ACC_2_[4-7]

h1susitmy (4):

H1:FEC-30_DAC_OVERFLOW_ACC_2_[4-7]

h1susauxb2h34 (3):

H1:SUS-BS_M1_NOISEMON_F[1-3]_OUT_DQ

As Jonathan details in his alog, after the restart of h1susauxb2h34 the DAQ was running with duplicate BS-AUX channels which had been added to h1susauxb2h34 and were still running on h1susauxb13 (a temporary model I built on Wed). This was resolved when the new h1susauxb13 was installed.

Restart Log

Thu15Jan2026
LOC TIME HOSTNAME     MODEL/REBOOT
12:32:41 h1susb2h34   h1susmc2    <<< First set of h1susb2h34 restarts
12:33:07 h1susb2h34   h1suspr2    
12:36:07 h1susb2h34   h1sussr2    
12:36:25 h1susb2h34   h1susbs     
12:45:57 h1susb2h34   h1suspr2    <<< Fix 18bit-DAC issue


13:07:10 h1susb2h34   h1susmc2    <<< Second set of h1susb2h34 restarts with fixed IPC
13:07:29 h1susb2h34   h1suspr2    
13:07:54 h1susb2h34   h1sussr2    
13:08:12 h1susb2h34   h1susbs     


13:32:14 h1daqdc1     [DAQ]  <<< DAQ 1-leg, new models and new EDC
13:32:25 h1daqfw1     [DAQ]
13:32:26 h1daqtw1     [DAQ]
13:32:29 h1daqnds1    [DAQ]
13:32:35 h1daqgds1    [DAQ]
13:32:51 h1susauxh56 h1edc[DAQ]  <<< EDC restart
13:34:56 h1daqgds1    [DAQ] <<< GDS1 needed second restart
13:36:31 h1daqgds0    [DAQ] <<< DAQ 0-leg
13:36:39 h1daqfw0     [DAQ]
13:36:39 h1daqtw0     [DAQ]
13:36:40 h1daqnds0    [DAQ]


14:50:28 h1susb13     h1susitmx   <<< New h1susb13 models
14:50:52 h1susb13     h1susitmy   
14:51:13 h1susb13     h1susitmpi  


14:57:31 h1daqdc1     [DAQ] <<< DAQ 1-leg restart for new models
14:57:41 h1daqfw1     [DAQ]
14:57:41 h1daqtw1     [DAQ]
14:57:43 h1daqnds1    [DAQ]
15:04:22 h1daqfw1     [DAQ]  <<< FW1 spontaneous restart
15:07:00 h1daqgds1    [DAQ] <<< GDS1 manual start after missing channels removed
15:09:02 h1daqfw1     [DAQ] <<< 2nd FW1 spontaneous restart
15:17:02 h1daqgds0    [DAQ] <<< 0-leg restart
15:17:09 h1daqfw0     [DAQ]
15:17:09 h1daqtw0     [DAQ]
15:17:10 h1daqnds0    [DAQ]


15:50:54 h1susauxb2h34 h1susauxb2h34 <<< new model (unknowingly adding duplicate chans)


15:54:02 h1daqdc1     [DAQ] <<< DAQ restart for model change, 1-leg
15:54:11 h1daqfw1     [DAQ]
15:54:11 h1daqtw1     [DAQ]
15:54:15 h1daqnds1    [DAQ]
15:54:20 h1daqgds1    [DAQ]
16:02:39 h1daqgds0    [DAQ] <<< 0-leg
16:02:45 h1daqfw0     [DAQ]
16:02:46 h1daqnds0    [DAQ]
16:02:46 h1daqtw0     [DAQ] <<< At this point FW2 is unstable due to duplicate channels, not sure why 0-leg & 1-leg are running at this point


17:23:09 h1susauxb13  h1susauxb13 <<< new model (removed duplicate BS chans)


17:23:53 h1daqdc1     [DAQ] <<< 1-leg
17:24:03 h1daqfw1     [DAQ]
17:24:03 h1daqtw1     [DAQ]
17:24:07 h1daqnds1    [DAQ]
17:31:19 h1daqgds1    [DAQ] <<< GDS1 manual restart after removing GDS chans from broadcaster
17:33:22 h1daqgds0    [DAQ] <<< 0-leg restart
17:33:27 h1daqfw0     [DAQ]
17:33:28 h1daqnds0    [DAQ]
17:33:28 h1daqtw0     [DAQ]
17:37:55 h1daqfw0     [DAQ] <<< FW0 spontaneous restart