VOPO measurement setup

Attached is the mode-matching layout for the VOPO. The target primary waist of the VOPO (from TT1700104) is 221.2um(s), 206um(t) for 1064nm and 159.2um(s), 148.8um(t) for 532nm.

The mode matched minor and major beam waist is 198.6um, 204.2um for 1064nm and 152.6um, 185um for 532nm. For the fundamental injection via the rear mirror, the measured waist is 197.25um, 231.85um. These waist is measured at the position marked with a "star". The mode-matching calculation has been reviewed by a fur-low scientist.

Images attached to this report
Non-image files attached to this report
Comments related to this report
karmeng.kwan@LIGO.ORG - 10:47, Wednesday 14 January 2026 (88763)

I have included a diagram showing the components remaining on the optical table, which can be used for testing the homodyne detector.

The attached file also includes the corresponding mode-matching calculation, indicating the resulting beam waist location along the remaining optical path, for future reference.

Non-image files attached to this comment
corey.gray@LIGO.ORG - 15:19, Tuesday 20 January 2026 (88811)

Tagging EPO for photo of fur-low scientist.