Reports until 14:46, Wednesday 21 January 2026
H1 SUS (CDS)
oli.patane@LIGO.ORG - posted 14:46, Wednesday 21 January 2026 (88819)
SUS Model Updates: h1susauxb13

Jeff, Oli

We made several updates to multiple SUS simulink models as a continuation of our work converting SUSB123 and SUSH34 into SUSB13 and SUSB2H34 (88765). Our changes were based on our updated G2301306-v10_PARTII - for the conversion from SUSB123 into SUSB13 for SUSAUXB13, we referenced slides 23 and 24. These changes were svn'd as r34396 and were installed and started last week (88781).

These are the changes we had to made for h1susauxb13 (previously called h1susauxb123):

CDS Parameter Block:
- Changed hostname from h1susauxb123 to h1susauxb13
- Removed specific_cpu

Input (before, after):
- Removed BS block
- Removed ADC6 and ADC7
- ADC0 flag going into ITMY block is now in ADC5
- ADC7 flag going into ITMY block is now in ADC0

ITMY block (before, after):
- Removed ADC7
- Everything that was previously ADC0 is now in ADC5
- Everything that was previously ADC7 is now in ADC0

Images attached to this report
Non-image files attached to this report