Reports until 14:23, Thursday 22 January 2026
H1 SUS
ryan.crouch@LIGO.ORG - posted 14:23, Thursday 22 January 2026 (88851)
OPO health check TFs

I ran some TFs on the OPO to do a health check, some things to note... The ISI was locked and tripped, we were in air, and the suspension's damping loops were on. I left its CD state as 2 as this SUS has its coil driver jumpered. 

Things look pretty noisy overall so its hard to say, I was struggling a bit to get good coherence without causing overflows, maybe due to the purge air? Especially with my L measurement, the next worse coherence was in T. I also noticed that H3s counts dropped quite a lot 2 days ago, over 10k counts.

I'd like to retake the whole measurment with the purge air turned down.

/ligo/svncommon/SusSVN/sus/trunk/OPOS/H1/OPO/SAGM1/Data
2026-01-22_2000_H1SUSOPO_M1_WhiteNoise_L_0p02to50Hz.xml
2026-01-22_2000_H1SUSOPO_M1_WhiteNoise_P_0p02to50Hz.xml
2026-01-22_2000_H1SUSOPO_M1_WhiteNoise_R_0p02to50Hz.xml
2026-01-22_2000_H1SUSOPO_M1_WhiteNoise_T_0p02to50Hz.xml
2026-01-22_2000_H1SUSOPO_M1_WhiteNoise_V_0p02to50Hz.xml
2026-01-22_2000_H1SUSOPO_M1_WhiteNoise_Y_0p02to50Hz.xml

Images attached to this report
Non-image files attached to this report