Displaying report 1-1 of 1.
Reports until 17:42, Thursday 22 January 2026
H1 SUS (CDS)
oli.patane@LIGO.ORG - posted 17:42, Thursday 22 January 2026 (88861)
Summary of Conversion from SUSB123 & SUSH34 to SUSB13 & SUSB2H34 ('No QOSEMs/BBSS' Configuration)

Here is the summary with all the relavant alogs for the conversion from SUSB123 and SUSH34 to SUSB13 and SUSB2H34*.

*Our current configuration, specifically for SUSB2H34, is an interim state ("No QOSEMs/BBSS" config) on the way to the final O5 configuration, so SUSB2H34 doesn't fully match the cabling diagrams seen in D2300383. We can't fully upgrade to this O5 version yet because we don't have the BBSS, LO1, or LO2 installed yet, and need to be able to actuate the BSFM for the February commissioning period. To see what still needs to be done to get from this interim period to the final O5 configuration, see 88860 and google slides.

SUSB13 wiring diagram: D2300401
SUSB2H34 wiring diagram: D2300383

CER hardware changes88765
    AI chassis upgrades: 88766
    New power rail in SUS-C1: 88850
    Fix for failed untouched chassis: 88849
    BIO cable naming convention: 88852
    Renaming of SR3 OPLEV cable: 88837
    Updated SUS-C1/C2/C5/C6 rack photos: 88848
    Current status of SUS-C1/C2 racks vs Final O5 build: 88860
SUS Model Updates:
    ITMX: 88812
    ITMY: 88813
    ITMPI: 88818
    BS: 88814
    MC2: 88815
    PR2: 88816
    SR2: 88817
    AUXB123 -> AUXB13: 88819
    AUXH34 -> AUXB2H34: 88820
SUS Model Installation: 88781

Displaying report 1-1 of 1.