Displaying report 1-1 of 1.
Reports until 16:48, Monday 02 February 2026
H1 CDS
david.barker@LIGO.ORG - posted 16:48, Monday 02 February 2026 (88996)
Restart h1susham1 model

Oli, Rahul, Tony, Marc, Fil, Daniel, Dave.

At 15:41 we restarted the h1susham1 model as part of the PM1 noise investigation. This did not change anything.

Later (16:40) Marc and Fil found that the problem was a dead power rail in the PM1 coil driver.

Displaying report 1-1 of 1.